Communication, Can port, Product description – Lenze 8400 protec Manual User Manual

Page 27: Communication can port

Advertising
background image

Product description

Communication

CAN port

3

l

27

EDS84DPS424 EN 5.0

3.5

Communication

The available combinations of communication and connection system can be seen from
the table.

Type code characteristics

Connection system version

Communication

(fieldbus)

Input /

output area

configuration

Fieldbus

SSI

3)

Analog input CAN on board

Push−pull

M12

M12

M12

M12

CANopen

1)

C

1

ю

ю

5

ю

ю

PROFIBUS

P

1

ю

ю

3

ю

ю

ю

2)

5

ю

ю

7

ю

ю

ю

2)

PROFINET / EtherNet/IP

1)

R / G

1

ю

ю

2

ю

ю

3

ю

ю

ю

2)

4

ю

ю

ю

2)

5

ю

ю

6

ю

ю

7

ю

ю

ю

2)

8

ю

ю

ю

2)

ю designed

1)

cannot be combined with safety options 20 and 30

2)

cannot be combined with safety option 30

3)

not in StateLine version

impossible

3.5.1

CAN port

Detailed information on CAN can be found in the software manual.

CAN on board

"CAN on board" is only suited for short point−to−point connections between two
controllers, e.g. for synchronisation. Pay attention to notes on EMC−compliant wiring and
short cable lengths as there is no isolation towards the control electronics of the controller.

Node address and baud rate must be parameterised using the »Engineer«.

CANopen

CANopen is executed as isolated fieldbus and suited for multiple−node networks.

In case of fieldbuses, node address and baud rate can be set using the DIP switch under the
service hatch or parameterised using the »Engineer«.