Diagnostics – Lenze 8400 protec Manual User Manual

Page 171

Advertising
background image

Diagnostics

Display of operating data, diagnostics

Drive diagnostics

10

l

171

EDS84DPS424 EN 5.0

Display parameters

The parameters listed in the following table serve to get information on current statuses
and actual values of the controller for diagnostic purposes, e.g. with the keypad, via a bus
system or using the »Engineer« (when an online connection has been established to the
controller)

– In the »Engineer« parameter list and in the keypad, these parameters are classified

in the Diagnostics category.

– A detailed description of these parameters can be found in the software manual of

the prevailing device version.

Parameter

Display

C00183

Device state

C00168

Error number

C00051

Actual speed value

C00052

Motor voltage

C00054

Motor current

C00057/1

Maximum torque

C00057/2

Torque at maximum current

C00059

Motor − number of pole pairs

C00061

Heatsink temperature

C00062

Temp. inside the controller

C00063

Motor temperature

C00064

Device utilisation (I x t) over the last 180 seconds

C00065

Ext. 24−V voltage

C00066

Thermal motor load (I

2

xt)

C00178

Time the controller was enabled (elapsed−time meter)

C00179

Time the mains was switched on (power−on time meter)

Identification data

The parameters listed in the following table which are classified in the »Engineer«
parameter list and the keypad in the category Identification

W Controller serve to display

the identification data of the controller.

Parameter

Display

C00099

Firmware version

C00200

Firmware product type

C00201

Firmware compilation date

C00203/1 ... 9

HW product types

C00204/1 ... 9

HW serial numbers

C00205/1 ... 6

HW descriptions

C00206/1 ... 6

HW manufacturing data

C00210/1 ... 6

HW version

Advertising