Terminal control, Commissioning – Lenze 8400 protec Manual User Manual

Page 146

Advertising
background image

Commissioning

Quick commissioning
Terminal control

8

l

146

EDS84DPS424 EN 5.0

8.3.2

Terminal control

Commissioning steps

1. Wiring of power terminals

Make use of the Mounting Instructions supplied with the frequency inverter to wire the
power terminals according to the requirements of your device.

2. Wiring of control terminals.

Analog inputs at X50

Assignment

Terminal control

X50

2

4I

A1

I

GA

A1

U

A

R

1

2

3

4

5

0...10V

1k
...
10k

Ω

Ω

A1U

Setpoint selection
10 V (=100 %):
1500 min

−1

(with 4−pole motor)

Wiring of the digital outputs at X41

Assignment

Terminal control

X41

2

4I

D

I2

G

IO

D

I1

1

2

3

4

DI1

Fixed frequency 1 ... fixed frequency 3, see
table below

DI1 ... DI2: active = HIGH

DI2

Wiring of the digital outputs at X42

Assignment

Terminal control

X42

24I

GIO

DI3

1

2

3

4

DI4

DI3

DCB

DI3 ... DI4: active = HIGH

DI4

Direction of rotation left/right (CCW/CW)

3. If you can be sure that the frequency inverter is in the default state (Lenze setting),

you can skip the following step. If not, establish the Lenze setting of the frequency
inverter. We recommend to use the keypad for this.

)

Note!

The application "actuating drive speed" is implemented with the Lenze
setting.