Technical data

General data and operating conditions

4

l

42

EDS84DPS424 EN 5.0

Mounting conditions

Mounting place

Wall
Ensure convection cooling in the niches.)

Mounting position

Standard mounting

Display to the front
Vertically suspended, −30 ... +30 °

In case of greater angles of tilt:
Operation at 2/4 kHz: > +40 °C: Reduce the rated output
current by 2.5 %/°C.
Operation at 8/16 kHz: > +35 °C: Reduce the rated output
current by 2.5 %/°C.

Free space

^ 72

Requirements on the motor cable

Capacitance per unit length

£ 1.5 mm

2

/AWG 16

C

Core/core

/C

Core/shield

£ 75/150 pF/m

³ 2.5 mm

2

/AWG 12

C

core/core

/C

Core/shield

£ 100/£ 150 pF/m

Electric strength

VDE 0250−1

U

0

/U

=

0.6/1.0 kV

(U

0

= r.m.s. value external − conductor/PE,

U = r.m.s. value − external conductor/external
conductor)

UL

U

³ 600 V

(U = r.m.s. value external conductor/external
conductor)