Technical data

Control terminals

Digital outputs

4

l

65

EDS84DPS424 EN 5.0

4.7.2

Digital outputs

X42 − configured

Labelling

Features

Rated value

4 / DO1
2 / DO2
3 / GIO

Digital output

According to IEC61131−2, type 1

External−voltage protected

up to +30 V
Integrated polarity reversal protection diode for
switching inductive loads

Isolation

^ 76

Level

LOW < +5 V
High > +15 V

Time−dependent behaviour

LOW − HIGH / HIGH − LOW
max. 250

ms

Behaviour during overload

Reduced voltage or periodic switch−off/on

Behaviour in case of reset and during
switch−on

Outputs are switched−off (LOW)

Cycle time

1 ms

Max. output current

200 mA per output

1 / 24O
3 / GIO

24 V supply of the external sensors or
potential−free contacts

External supply at 24E: Voltage drop < 2.5 V

Total current for X4x, X50/X8x

1 A

Extensions in the EMS version

X46 − configured

Labelling

Features

Rated value

4 / DO3
2 / DO4
3 / GIO

Digital output

According to IEC61131−2, type 1

External−voltage protected

up to +30 V
Integrated polarity reversal protection diode for
switching inductive loads

Isolation

^ 76

Level

LOW < +5 V
High > +15 V

Time−dependent behaviour

LOW − HIGH / HIGH − LOW
max. 250

ms

Behaviour during overload

Reduced voltage or periodic switch−off/on

Behaviour in case of reset and during
switch−on

Outputs are switched−off (LOW)

Cycle time

1 ms

Max. output current

200 mA per output

1 / 24O
3 / GIO

24 V supply of the external sensors or
potential−free contacts

External supply at 24E: Voltage drop < 2.5 V

Total current for X4x, X50/X8x

1 A