Control terminals digital inputs and outputs, Example circuit – Lenze 8400 protec Manual User Manual

Page 96

Advertising
background image

Electrical installation − HighLine/StateLine version

Control terminals
Digital inputs and outputs

6

l

96

EDS84DPS424 EN 5.0

X43 − digital inputs DI5, DI6

Pin

Signal

Description

Data

Type M12, 5−pole sockets

84DPSO05_5

1

24O

24 V supply of the external sensors

2

DI6

Digital input 6

According to IEC61131−2, type 1
or
Single−channel frequency input, 0 ... 10
kHz

3

GIO

Reference potential

HIGH
LOW

+15 .... +30 V DC
0 ... +5 V

4

DI5

Digital input 5

8 mA at 24 V DC

5

n. c.

Not assigned

Example circuit

0

1

DI1

S1

X41

GND-IO

GIO

24O

3.3k

3.3k

DI2

S2

=

-

+

DI1

X41

GND-IO

GIO

24O

3

.3k

3

.3k

DI2

"

8400DIO045

8400DIO022

Fig. 6−6

Wiring examples of the digital inputs
0

Wiring of digital inputs, examples:

S1

Potential−free contact, at internal 24 V supply

S2

Signal source, e.g. PLC or with external 24 V supply

1

Connection of an HTL incremental encoder with a maximum input frequency of
100 kHz
DI1

track A

DI2

track B

X41

Plugs for digital inputs X41 ... X43

GIO

Ground reference potential for the digital inputs and outputs (GND−IO)

Advertising