Technical data

Control terminals
Digital inputs

4

l

64

EDS84DPS424 EN 5.0

4.7

Control terminals

4.7.1

Digital inputs

X41 ... X43

Pin / Name

Features

Rated value

4 / DI1
2 / DI2

Digital input 1/2 at X41

according to IEC 61131−2, type 1
or
two−track frequency input for HTL encoder
0 ... 100 kHz

4 / DI3
2 / DI4

Digital input 3/4 at X42

according to IEC 61131−2, type 1
DI4 − typical delay time:

l

5

ms at rising edge

l

25

ms at falling edge

4 / DI5
2 / DI6

Digital input 5/6 at X43

according to IEC 61131−2, type 1
or
Single−channel frequency input, 0 ... 10 kHz
DI5/DI6 − typical delay time:

m

l

5

ms at rising edge

l

25

ms at falling edge

1 / 24O
3 / GIO

24 V supply of the external sensors or
potential−free contacts

External supply at 24E: Voltage drop < 2.5 V

Total current for X4x, X50/X8x

1 A

Extensions in the EMS version

X45 ... X48

Pin / Name

Features

Rated value

4 / DI7
2 / DI8

Digital input 7/8 at X45

according to IEC 61131−2, type 1

4 / DI9
2 / DI10

Digital input 9/10 at X46
(configurable with DO3/DO4)

4 / DI11
2 / DI12

Digital input 11/12 at X47

4 / DI13
2 / DI14

Digital input 13/14 at X48

5 / n. c.

not assigned

1 / 24O
3 / GIO

24 V supply of the external sensors or
potential−free contacts

External supply at 24E: Voltage drop < 2.5 V

Total current for X41 ... X48

1 A