Electrical installation − EMS version

Control terminals

Interfaces RS485/422 PLC

7

l

133

EDS84DPS424 EN 5.0

7.6.4

Interfaces RS485/422 PLC

These connections are available with device versions:

ƒ

E84DDxxxxxxxC1Cxxx

ƒ

E84DExxxxxxxC1Cxxx

ƒ

E84DFxxxxxxxC1Cxxx

ƒ

E84DLxxxxxxxC1Cxxx

ƒ

E84DPxxxxxxxC1Cxxx

X81 − RS485 PLC

Pin

Signal

Description

Data

84DPSO05_8

M12 type, 8−pole sockets, A−coded

1

+24V

24 V supply

In accordance with IEC 61131−2, type 1

3

GND−EXT

Reference potential

2

RxD+

RS485A’

In accordance with ANSI/TIA/EIA−485−A−98

4

RxD−

RS485B’

5

TxD+

RS485A

6

TxD−

RS485B

7

n. c.

Not assigned

8

n. c.

X82 − RS422 PLC

Pin

Signal

Description

Data

84DPSO05_8

M12 type, 8−pole sockets, A−coded

1

+24V

24 V supply

In accordance with IEC 61131−2, type 1

3

GND−EXT

Reference potential

2

RxD+

Reception+

In accordance with ANSI/TIA/EIA−422

4

RxD−

Reception−

5

TxD+

Transmission+

6

TxD−

Transmission−

7

n. c.

Not assigned

8

n. c.

Please observe that the direct coupling of two 8400 protec EMS devices require an external
connection with terminating resistors.