Rated data, Overview, Technical data – Lenze 8400 protec Manual User Manual

Page 46

Advertising
background image

Technical data

Rated data
Overview

4

l

46

EDS84DPS424 EN 5.0

4.2

Rated data

4.2.1

Overview

Basis of the data

Mains

Voltage

Voltage range

Frequency range

U

Lrated

[V]

U

Lrated

[V]

f [Hz]

3/PE AC

400

320 − 0 % ... 440 + 0 %

45 − 0 % ... 65 + 0 %

3/PE AC

500

400 − 0 % ... 550 + 0 %

45 − 0 % ... 65 + 0 %

Output switching frequency f = 4 kHz

Input data

Voltage

Frequency

Rated current [A]

Number of

phases

[V]

[Hz]

up to +45 °C



up to +55 °C



E84Dxxxx7514

400/500

50/60

4.1/3.2

3.0/2.4

3

E84Dxxxx1524

400/500

50/60

5.5/4.4

3.5/3.1

3

E84Dxxxx3024

400/500

50/60

9.7/7.9

7.3/6.0

3

E84Dxxxx4024

400/500

50/60

12.9/11.0

9.5/8.1

3

E84DHxxx7524

400/500

50/60

20.8/16.6

15.6/12.5

3

 Ambient temperature during operation

Rated data of the 24−V buffer voltage (preserves the control functionality in the event of
a mains failure):

Supply voltage for control electronics of the controller

(safely separated power supply unit SELV/PELV)

Typ

Voltage range U

DC

[V DC]

Current consumption at + 24 V DC [A]

Min.

1)

Max.

2)

E84Dxxxx7514

+ 24

(+19.2 − 0 % ... +28.8 + 0 %)

0.2 ... 0.6

2

E84Dxxxx1524

E84Dxxxx3024

E84Dxxxx4024

E84DHxxx7524

1)

according to optional equipment, digital inputs and outputs are not wired

2)

digital inputs and outputs are completely wired

)

Note!

The maximum total current of the 24 V voltage supply for external actuators
and encoders is 1 A, e.g. ports

ƒ

Digital inputs/outputs at X4x,

ƒ

Analog input at X50 or SSI at X80, and

ƒ

Serial interfaces RS485/RS422 at X81/X82.

Advertising