Interfaces of the ems version, Technical data – Lenze 8400 protec Manual User Manual

Page 67

Advertising
background image

Technical data

Control terminals

Interfaces of the EMS version

4

l

67

EDS84DPS424 EN 5.0

4.7.6

Interfaces of the EMS version

CANopen Master PLC

X34

Pin / Name

Features

Rated value

1 /

"

Shielding (functional earth)

2 / n. c.

not assigned

3 / CAN_GND

CAN GND

Bit rate: adjustable up to 1 Mbit
Isolation: Function separation

4 / CANH

CAN HIGH

5 / CANL

CAN LOW

RS485/422 PLC

X81/X82

Pin / Name

Features

Rated value

RS485

RS422

The
assignment
depends on the
device version
(

^ 133).

24 V supply

according to IEC 61131−2, type 1

RS485A’

Reception + (Data+)

l

according to:
– ANSI/TIA/EIA−485−A−98
– ANSI/TIA/EIA−422

l

Bit rate: Adjustable up to 115.2 kbit

l

Isolation: Function separation

l

At RS422, PLC supports evaluation of SSI
encoders (max. 150 kHz).

RS485B’

Reception (Data−)

RS485A

Transmission+ (CLK+)

RS485B

Transmission− (CLK−)

Infrared interface (IrDA)

IrDA (Infrared Data Association)

Pin / Name

Features

Rated value

Reach

~1 m

Angle of incidence

~30 °