Safety engineering – Lenze 8400 protec Manual User Manual

Page 104

Advertising
background image

Electrical installation − HighLine/StateLine version

Safety engineering

6

l

104

EDS84DPS424 EN 5.0

X62 − connection of safety engineering system "Safety Option 30"

Pin

Connection

Description

Data

M12, 5−pole sockets, A−coded

84DPSO05_5

1

AIE

Error acknowledgement

2

24_ACK

24−V supply voltage for reset button

max. 300 mA

3

AIS

Restart acknowledgement

4

GND_SM

GND potential

5

GND_SM

X63 − connection of the "Safety Option 30" safety engineering system

Pin

Connection

Description

Data

M12, sockets 8−pole, A−coded

84DSO05_8

1

CLA

Clock output, channel A

2

CLB

Clock output, channel B

3

GND_CLK

GND potential − clock output, channel A

4

I1A

Safe input 1, channel A

5

GND_I1

GND potential − input 1, channel A

6

I1B

Safe input 1, channel B

7

GND_CLK

GND potential − clock output, channel B

8

GND_I1

GND potential − input 1, channel B

X64 − connection of the "Safety Option 30" safety engineering system

Pin

Connection

Description

Data

M12, sockets 8−pole, A−coded

84DSO05_8

1

CLA

Clock output, channel A

2

CLB

Clock output, channel B

3

GND_CLK

GND potential − clock output, channel A

4

I2A

Safe input 2, channel A

5

GND_I2

GND potential − input 2, channel A

6

I2B

Safe input 2, channel B

7

GND_CLK

GND potential − clock output, channel B

8

GND_I2

GND potential − input 2, channel B