Drive diagnostics, Diagnostics – Lenze 8400 protec Manual User Manual
Page 170
Diagnostics
Display of operating data, diagnostics
Drive diagnostics
l
170
EDS84DPS424 EN 5.0
10.1.5
Drive diagnostics
The controller measures relevant operating parameters which can be displayed using the
diagnosis terminal or the PC.
Display of the controller status on the keypad
– If the keypad at the front of the controller is connected to the
diagnostic interface X6, the area
of the LCD displays the
controller status via different symbols.
Icon
Meaning
Note
d
Controller is switched on.
à
"SwitchedON" state
Controller is enabled.
Application in the controller is stopped.
Quick stop is active.
Controller is inhibited.
The power outputs are inhibited.
Controller is ready to start
à
"ReadyToSwitchOn" state
¥
Speed controller 1 in the limitation
The drive is torque−controlled.
¦
The set current limit is exceeded in motor
or generator mode
§
Pulse inhibit is active
The power outputs are inhibited.
System fault is active
Fault
à
"Fault" state
Trouble
à
"Trouble" state
¡
TroubleQSP
à
"TroubleQSP" state
¢
Warning is active
à