Diagnostics

Display of operating data, diagnostics
Status display of the safety system via LEDs at the controller

10

l

162

EDS84DPS424 EN 5.0

Pos.

Colour

State

Description

DI7

yellow

on

DI7 = HIGH

off

DI7 = LOW

DI8

yellow

on

DI8 = HIGH

off

DI8 = LOW

DI9/DO3

yellow

on

DI9/DO3 = HIGH

off

DI9/DO3 = LOW

DI10/DO4

yellow

on

DI10/DO4 = HIGH

off

DI10/DO4 = LOW

DI11

yellow

on

DI11 = HIGH

off

DI11 = LOW

DI12

yellow

on

DI12 = HIGH

off

DI12 = LOW

DI13

yellow

on

DI13 = HIGH

off

DI13 = LOW

DI14

yellow

on

DI14 = HIGH

off

DI14 = LOW

10.1.3

Status display of the safety system via LEDs at the controller

Status display: drive−based safety

Pos.

Colour

State

Description

S−State

green

on

Communication between standard device and safety system
is running

blinking

Drive−based safety is in service status

off

Communication between standard device and safety system
is not possible

S−Error

red

on

Fault, trouble or warning

blinking

Drive−based safety is not accepted by the standard device

off

Error−free operation

S−Acknw

yellow

on

A parameter set acceptance must be acknowledged

S−Enable

yellow

on

Controller is enabled

blinking

Safety function is active (non−safe display)

The status of safety option 10 is solely shown via the "S−Enable" display. All other displays have no function.

}

Danger!

Danger to life due to wrong interpretation of the status display
A wrong interpretation of the status display of the drive−based safety may
result in dangerous operating statuses.
Possible consequences:

ƒ

Death or severe injuries

Protective measures:

ƒ

The status display of the drive−based safety must not be used for
safety−related purposes. The displays shown are unsafe.

Advertising