Diagnostics

Display of operating data, diagnostics

Drive diagnostics via the integrated display

10

l

167

EDS84DPS424 EN 5.0

Error

Group

Setting

CAN code

Reaction

Text

Abbr.

Number

ID

123

99 0x1763

FC1

Limitation of field controller

No reaction

0xF000

C00570/4

94 0x175e

FCH1

Switching frequency reduction

No reaction

0x2000

C00590

95 0x175f

FCH2

Maximum speed for Fchop

No reaction

0xF000

C00588

57 0x1739

ID1

Error: Motor data identification

WarningLocked

0xF000

58 0x173a

ID3

CINH motor data identification

WarningLocked

0xF000

59 0x173b

ID4

Error in resistor identification

Warning

0xF000

145 0x1791

LP1

Motor phase failure

No reaction

0x3000

C00597

15 0x170f

LU

DC bus undervoltage

Trouble

0x3100

C00600/1

16 0x1710

OC1

Power section short circuit

Fault

0x2000

17 0x1711

OC2

Power section earth fault

Fault

0x2000

105 0x1769

OC6

I

2

xt overload − motor

Warning

0x2000

C00606

7 0x1707

OC7

Motor overcurrent

Fault

0x2000

30 0x171e

OC10

Maximum current reached

Fault

0x2000

71 0x1747

OC11

Clamp operation active

Warning

0xF000

65 0x1741

OC12

I

2

xt overload − brake resistor

Fault

0xF000

90 0x175a

OC13

Exceedance of maximum current for
Fch

Fault

0xF000

96 0x1760

OC14

Limitation of direct−axis current
controller

No reaction

0xF000

C00570/1

97 0x1761

OC15

Limitation of cross current controller

No reaction

0xF000

C00570/2

98 0x1762

OC16

Limitation of torque controller

No reaction

0xF000

C00570/3

31 0x171f

OC17

Clamp sets pulse inhibit

No reaction

0xF000

C00569/1

32 0x1720

OS1

Maximum speed limit reached

No reaction

0x8400

C00579

1 0x1701

OT1

Maximum torque reached

No reaction

0x8300

C00608

93 0x175d

OT2

Speed controller output limited

No reaction

0xF000

C00567

14 0x170e

OU

DC bus overvoltage

Trouble

0x3100

205 0x17cd

SD3

Open circuit − feedback system

Fault

0x7300

C00586

200 0x17c8

SD10

Speed limit − feedback system 12

Fault

0x7300

C00607

201 0x17c9

SD11

Speed limit − feedback system 67

Fault

0x7300

C00607

125

1 0x1901

An01

AIN1_I < 4 mA

TroubleQuickStop 0xF000

C00598/1

11 0x190b

Io11

DigOut level

Warning

0xF000

C00598/3

127

2 0x1b02

CE04

MCI communication error

No reaction

0x7000

C01501/1

15 0x1b0f

CE0F

MCI control word

Fault

0xF000

C00594/2

128

5 0x1c05

EDB1

EMS half wave error

No reaction

C00596/5

6 0x1c06

EHV1

EMS PowerwaveFail

No reaction

C00596/6

7 0x1907

EPV2

EMS DeCaBus error

No reaction

C00596/7