Diagnostics

Display of operating data, diagnostics
Status display of the safety system via LEDs at the controller

10

l

164

EDS84DPS424 EN 5.0

The LEDs "DRIVE READY" and "DRIVE ERROR" can blink in different ways depending on the
device states which are explained in the following. This permits an easy device diagnostics
without additional tools.

DRIVE READY

(green)

DRIVE ERROR

(red)

Status

Description

OFF

OFF

® "Init" state

Initialisation is active

OFF

® "MotorIdent" state

Motor data identification

– The "MotorIdent" device state can

only be reached by the "SwitchON"
device state and jumps back to that
state after the action is completed.

OFF

® "SafeTorqueOff" state

This state is only possible in relation with a
connected safety module and an existing
power section supply!

OFF

® "ReadyToSwitchOn" state

Device is ready to start

– This is the controller’s state directly

after the initialisation has been
completed.

OFF

® "SwitchedOn" state

Device is switched on

– This is the controller’s device state if

the DC bus voltage is applied and the
controller is still inhibited by the user
(controller inhibit).

OFF

® "OperationEnabled" state

Operation

– In this device state, the motor follows

the setpoint defined in the
application.

® "Warning" status display

Operation/warning is active

– This display may occur in all device

states if a monitoring mode responds
the error response "Warning" or
"Warning locked" has been
parameterised for.

® "TroubleQSP" state

TroubleQSP is active

– This device state will be active as soon

as a monitoring mode responds, the
error response "TroubleQSP" has been
parameterised for.

OFF

® "Trouble" state

Message is active

– This device state will be active as soon

as a monitoring mode responds, the
error response "Message" has been
parameterised for.

OFF

® "Fault" state

Fault is active

– This device state will be active as soon

as a monitoring mode responds, the
error response "Fault" has been
parameterised for.

OFF

® "SystemFail" state

System fault is active

– This device state will be active if a

system fault occurs.