Lenze 8400 protec Manual User Manual

Page 107

Advertising
background image

Electrical installation − EMS version

Important notes

7

l

107

EDS84DPS424 EN 5.0

)

Note!

Only with the control element

ƒ

C = service switch with protective function

the device can be disconnected from the mains voltage.

)

Note!

The counter plugs of the power terminals must be equipped with connector
housings with a vertical outgoing cable.

)

Note!

ƒ

It is absolutely necessary to keep the plastic caps on the connectors for the
control terminals and interfaces!

ƒ

During transport, storage, and operation, ports not used must be sealed
using the plastic caps, in order to maintain the product features in
accordance with the technical data.

ƒ

Only if this note is observed, the product features certified are ensured for
devices with a safety system.

EMC−compliant wiring

)

Note!

ƒ

Establish a good conductive connection to protective earth by means of a
copper−braid cable (e.g. mounting surface, machine earth or building earth).

ƒ

Lay control cables and data lines separately from the motor cables.

ƒ

Connect the shields of the control cables and data lines at both ends.