Memory module

E84AYM30S

12

l

183

EDS84DPS424 EN 5.0

12.3.2

E84AYM30S

Name: Memory module (for EMS version)

Type designation: E84AYM30S (/M = 5 pcs/VPE)

Slot: MMI

The parameters o the controller are stored in the memory module. Moreover, this module
has further memory capacity for PLC programs and retain variables.

The pluggable memory module enables a quick parameter set transfer to an identical
controller. Possible reasons for a parameter set transfer are:

ƒ

Duplication of similar applications in a series of identical drives.

ƒ

Restorage of an application after device replacement.

The required steps for a parameter set transfer are described in the software manual.

In order to remove the memory module, use a suitable screwdriver to lever the module out
at the upper and lower groove. In order to plug in the module, insert it into the slot and push
it with light pressure until end position is reached.