Technical data, Rated data operation at rated mains voltage 400 v, 725 v, adjustable – Lenze 8400 protec Manual User Manual

Page 49

Advertising
background image

Technical data

Rated data

Operation at rated mains voltage 400 V

4

l

49

EDS84DPS424 EN 5.0

Rated data for internal brake chopper

Switching threshold V

BRmax

: 725 V, adjustable

R

Bmin

[

W]

I

BRmax

[A]

P

BRmax

[kW]

I

BRd

[A]

P

Bd

[kW]

t

Z

[s]

t

on

[s]

t

fp

[s]

Type

Internal brake resistor

E84Dxxx7514
E84Dxxx1524

220

3.3

2.4

0.5

0.05

1)

E84Dxxx3024
E84Dxxx4024
E84Dxxx7524

External brake resistor

E84Dxxx7514

150

4.8

3.5

1.4

0.9

300

60

E84Dxxx1524

150

4.8

3.5

2.9

2.0

300

60

E84Dxxx3024

47

15.4

11.2

5.7

3.9

300

60

E84Dxxx4024

47

15.4

11.2

7.5

5.2

300

60

E84Dxxx7524

47

15.4

11.2

14.1

9.8

300

60

R

Bmin

Minimum brake resistance, nominal value ±10 %

I

BRmax

Peak current

P

BRmax

Peak braking power

I

BRd

Continuous current RMS − important for the dimensioning of the cables

P

Bd

Continuous braking power

t

Z

Cycle time, periodic load change with running time and recovery time

t

on

Running time

t

Z

− t

on

Recovery time

t

fp

Maximum running time without initial load and compliance with the recovery
time

1)

Max. heat Q

B

: 3 kWs

Max. power loss in the internal brake resistor P

Bdav

: see table

f

ch

I

a

P

Bdav

[W]

[kHz]

[A]

T

amb

20 °C

30 °C

40 °C

45 °C

E84Dxxx7514

4

2.4

50

47

27

1.4

50

41

21

8

2.4

48

34

21

1.4

36

23

10

E84Dxxx1524

4

3.9

42

28

8

2.34

50

47

27

8

3.9

22

9

0

2.34

48

34

21

f

ch

Output switching frequency

I

a

Motor current

P

Bdav

Permissible power loss in the internal brake resistor, averaged over 60 s and
dependent on T

amb

(Linear interpolation/extrapolation via T

amb

is permissible. Here, the

application must limit the power loss in the brake resistor to P

Bdav

£ P

Bd

.)

T

amb

Ambient temperature

Advertising