Product description, Device features, 3product description – Lenze 8400 protec Manual User Manual

Page 20: 1 device features

Advertising
background image

Product description

Device features

3

l

20

EDS84DPS424 EN 5.0

3

Product description

3.1

Device features

Decentralised 8400 protec frequency inverter

Version

Features

HighLine

StateLine

EMS

Power range

0.75 ... 7.5 kW

0.75 ... 4 kW

0.75 ... 7.5 kW

Mounting type

Wall−mounted device

Brake management

Control of a mechanical motor holding brake

24 V supply

Internal (depending on mains voltage)

ь

ь

ь

24 V buffer voltage possible
(for maintaining the control functionality
in the case of mains failure)

ь

ь

Interfaces

Digital inputs,

6

6

14

can be configured as outputs

2

2

2 or 4

Analog inputs

1

1

1

or optionally synchronous serial interface
(SSI)

Optional: RS485 or/and RS422

2 x RS485
2 x RS422

1 x RS485 / RS422

each

Remote control, infrared (IrRC)

ü (from SW V12)

ü

Data interface, infrared (IrDA)

ü

Optional:

Drive−based safety

Safety option (SO) 10, 20 or 30

Operation in generator mode

Internal or external brake resistor

Control element

Various service switches

Rocker switch

Operation

200 % overload current for 3 s

ь

ь

ь

S ramps for jerk−free acceleration and
deceleration

ь

ь

ь

Protection against restart for cyclic mains
switching

ь

ь

ь

Technology applications

Speed actuating drive

ь

ь

ь

Switch−off positioning

ь

ь

ь

Absolute positioning

ь

ь

Table positioning

ь

ь

EMS−specific communication

Half wave

ü

Half wave coded

ü

Power wave

ü

DECA BUS

ü

Inductive energy transmission

ü

PLC functionality

ь

Advertising