Electrical installation − ems version, Control terminals digital inputs and outputs – Lenze 8400 protec Manual User Manual

Page 129

Advertising
background image

Electrical installation − EMS version

Control terminals

Digital inputs and outputs

7

l

129

EDS84DPS424 EN 5.0

X43 − digital inputs DI5, DI6

Pin

Signal

Description

Data

Type M12, 5−pole sockets

84DPSO05_5

1

24O

24 V supply of the external sensors

2

DI6

Digital input 6

According to IEC61131−2, type 1
or
Single−channel frequency input, 0 ... 10
kHz

3

GIO

Reference potential

HIGH
LOW

+15 .... +30 V DC
0 ... +5 V

4

DI5

Digital input 5

8 mA at 24 V DC

5

n. c.

Not assigned

X45 − digital inputs DI7, DI8

Pin

Signal

Description

Data

84DPSO05_5

Type M12, 5−pole sockets

1

24O

24 V supply of the external sensors

2

DI8

Digital input 8

HIGH

+15 .... +30 V DC

3

GIO

Reference potential

LOW

0 ... +5 V

4

DI7

Digital input 7

8 mA at 24 V DC

5

n. c.

Not assigned

X46 − digital inputs DI9, DI10

Pin

Signal

Description

Data

84DPSO05_5

Type M12, 5−pole sockets

1

24O

24 V supply of the external sensors

2

DI10
(DO4)

Digital input 10
(also available as digital output)

HIGH

+15 .... +30 V DC

3

GIO

Reference potential

LOW

0 ... +5 V

4

DI9
(DO3)

Digital input 9
(also available as digital output)

8 mA at 24 V DC

5

n. c.

Not assigned

X47 − digital inputs DI11, DI12

Pin

Signal

Description

Data

84DPSO05_5

Type M12, 5−pole sockets

1

24O

24 V supply of the external sensors

2

DI12

Digital input 12

HIGH

+15 .... +30 V DC

3

GIO

Reference potential

LOW

0 ... +5 V

4

DI11

Digital input 11

8 mA at 24 V DC

5

n. c.

Not assigned