Technical data

General data and operating conditions

4

l

43

EDS84DPS424 EN 5.0

EMC

Noise emission

Cable−guided

EN 61800−3

Up to 20 m shielded motor cable (Lenze system cable):
category C2

Radiation

Category C2

Noise immunity (according to requirements of EN 61800−3)

Electrostatic discharge
(ESD)

EN 61000−4−2

8 kV with air discharge,
4 kV with contact discharge against housing

Radio frequency

Cable−guided

EN 61000−4−6

150 kHz ... 80 MHz, 10 V/m 80 % AM (1kHz)

Interference (housing) EN 61000−4−3

80 MHz ... 1000 MHz, 10 V/m 80 % AM (1kHz)

Burst

Power terminals and
interfaces

EN 61000−4−4

2 kV/5 kHz

Signal interfaces

EN 61000−4−4

1 kV/5 kHz

Control terminals

EN 61000−4−4

2 kV/5 kHz

Surge

Power terminals

EN 61000−4−5

1.2/50

ms,

1 kV phase/phase, 2 kV phase/PE

Control terminals

EN 61000−4−5

1.2/50

ms, 1 kV

Operation on public supply
systems

EN 61000−3−2
EN 61000−3−12

The devices are intended for use in an industrial
environment. When being used on public network,
additional measures must be taken to limit the expected
radio interference. The compliance with the requirements for
the machine/plant is the responsibility of the manufacturer
of the machine or system!

EN 61000−3−2

< 0.5 kW: with mains choke

0.5 ... 1 kW: with active filter

> 1 kW at mains current

£ 16 A: No limit values for harmonic

currents

EN 61000−3−12

Mains current > 16 A: further measures are required for
compliance with the standard