Commissioning

Preparing the commissioning procedure

8

l

140

EDS84DPS424 EN 5.0

8.2

Preparing the commissioning procedure

You need the following for commissioning:

ƒ

Computer with a Windows® operating system (XP, 7 or 2000)

ƒ

Lenze »Engineer« PC software

ƒ

Connection to the controller via an interface, e.g.
– diagnostic interface X70 with diagnostic USB adapter
– Fieldbus

ƒ

Software manual for the technology application used

ƒ

Hardware manual (GHB)

ƒ

Manual for the drive−based safety

ƒ

Communication manual for the network of the automation platform

ƒ

24 V voltage supply for the control electronics of the controller
– by switching on the mains voltage
– alternatively by a 24−V buffer voltage

Follow the instructions of the software and/or read the documentation.

Selection of the appropriate commissioning tool

There are two ways to commission the 8400 frequency inverter:

ƒ

Commissioning using the keypad (or diagnosis terminal)
– For simple drive tasks such as quick commissioning of the ’Speed closed−loop

control’ standard application

ƒ

Commissioning using the »Engineer«
– For rather demanding drive tasks such as ’Table positioning’ of the HighLine

version

– Supported by online help and accompanying software documentation (software

manual)

)

Note!

The following can be used at the diagnostic interface X70:

ƒ

Diagnosis terminal X401 (EZAEBK2003)
– The described settings with the keypad X401 can also be carried out with

the diagnosis terminal X401.

ƒ

USB diagnostic adapter (E94AZCUS)