Motor holding brake connection, Technical data – Lenze 8400 protec Manual User Manual

Page 68

Advertising
background image

Technical data

Control terminals
Motor holding brake connection

4

l

68

EDS84DPS424 EN 5.0

4.7.7

Motor holding brake connection

Version according to type code: B (AC voltage: fast switch)

X21

Pin / Name

Feature

Rated value

Connection of a motor holding brake to the external brake rectifier in the motor terminal box
Max. switching capacity

55 W

Internal switching time

< 10 ms

Isolation

Basic insulation (

^ 76)

Time−dependent behaviour

See software manual, chapter holding brake
control / parameterisation

Behaviour in case of reset and during
switch−on

Outputs are switched−off / open

Operating frequency

Max. 60/min

Short−circuit strength

no

c2 / ~
c3 / ~

Switched mains voltage (L1/L2) for a brake rectifier
Switching voltage

AC 400/480 V according to IEC 61131−2

c4 / S1
c5 / S2

Potential−free contact for switching the brake rectifier on the DC side
Switching voltage

DC 250 V

Version according to type code: F (DC voltage: integrated brake rectifier)

X21

Pin / Name

Feature

Rated value

6 / BD1
4 / BD2

Connection of a motor holding brake
Integrated brake rectifier

Half−wave rectification with increased ripple

Output voltage
(dependent on mains voltage)

AC 400 V

DC 180 V

AC 500 V

DC 225 V

Max. output power

55 W

Internal switching time

< 1 ms

Time−dependent behaviour

See software manual, chapter holding brake
control / parameterisation

Short−circuit strength

no

Behaviour in case of reset and during
switch−on

Outputs are switched off

Operating frequency

Max. 60/min

Version according to type code: V (24 V DC Voltage)

X21

Pin / Name

Feature

Rated value

6 / BD1
4 / BD2

Connection of a motor holding brake
Output voltage
(dependent on input voltage)

DC 24 V

Max. output power

48 W

Internal switching time

< 1 ms

Time−dependent behaviour

See software manual, chapter holding brake
control / parameterisation

Short−circuit strength

Yes

Behaviour in case of reset and during
switch−on

Outputs are switched off

Operating frequency

Max. 60/min