RSLogix 5000 software performs configuration data checking as specified by the
limits shown in the data tables. The data checking verifies that the entry is within
range for the device, however, it does not verify that it is reasonable for the
application. You must be sure that the entry is reasonable for the specific
application. If you enter an out-of range parameter in a Configuration tab, a
message box reports the error and the appropriate limits.

Refer to

Chapter 6

for information on the limits specified by the data tables.

Generator Tab

The Generator tab is used to configure the unit to the design ratings of the
generator. Enter the generator’s nameplate ratings in the appropriate fields of the
Generator tab.

Rated Frequency - Sets the generator's rated frequency in Hz. Sets the value of tag
GenRatedFreq

in the Configuration table.

Rated Voltage - Sets the generator's rated line-to-line voltage in volts AC. Sets the
value of tag GenRated_V in the Configuration table.

Rated Current - Sets the generator's rated current in amperes AC. Sets the value
of tag GenRated_I in the Configuration table.