:SYSTem:SAVer

Syntax

:SYSTem:SAVer {ON|OFF}
:SYSTem:SAVer?

Description

Enable or disable the screen saver function.
Query the status of the screen saver function.

Parameter

Name

Type

Range

Default

{ON|OFF}

Bool

ON|OFF

OFF

Explanation

When the screen saver function is enabled, the instrument will enter the screen

saver mode automatically after standing by for 25 minutes and will enter the black

screen state after another 12.5 minutes.

Return Format

The query returns ON or OFF.

Example

:SYST:SAV ON /*Enable the screen saver function*/
:SYST:SAV? /*Query the status of the screen saver function and the query

returns ON*/

:SYSTem:SELF:TEST:BOARD?

Syntax

:SYSTem:SELF:TEST:BOARD? [{TOP|BOTTOM}]

Description

Query the self-test results of TopBoard and BottomBoard.

Parameter

Name

Type

Range

Default

{TOP|BOTTOM}

Discrete

TOP|BOTTOM

None

Explanation

 TOP: query the self-test result of TopBoard; BOTTOM: query the self-test result

of BottomBoard; when the parameter {TOP|BOTTOM} is omitted, the

command queries the self-test results of TopBoard and BottomBoard at the

same time.

 You can also send the

*TST?

command to query the self-test results of the

instrument (including the self-test results of the TopBoard, BottomBoard and

fan).

Return Format

The query returns PASS or FAIL. When the parameter {TOP|BOTTOM} is omitted,

the query returns the self-test results of TopBoard and BottomBoard (separated by

comma) at the same time, for example, PASS,PASS.

Example

:SYST:SELF:TEST:BOARD? /*Query the self-test results of TopBoard and

BottomBoard and the query returns PASS,PASS*/