RIGOL DP832A User Manual

Page 21

Advertising
background image

Chapter 1 Programming Overview

RIGOL

DP800 Programming Guide

1-11

Questionable Status Register of Single-channel Model

The SCPI status system of the single-channel model is as shown in Figure 1-3. Wherein, the questionable

status register provides voltage control, current control, over-temperature, overvoltage, overcurrent and

fan failure information. You can send the

:STATus:QUEStionable[:EVENt]?

command to read the register.

The definitions of the bits in the questionable status register of the single-channel model and the decimal

values corresponding to their binary weights are as shown in Table 1-4.

Table 1-4 Definitions of the bits in the questionable status register of the single-channel model and the

decimal values corresponding to their binary weights

Bit

Decimal Value Definition

0

VOLTage

1

The power supply is working in constant current

mode and the voltage becomes unregulated.

1

CURRent

2

The power supply is working in constant voltage

mode and the current becomes unregulated.

2-3

Not used

0

Always be 0.

4

TEMPerature

16

Over-temperature.

5-8

Not used

0

Always be 0.

9

OVP

512

Overvoltage.

10

OCP

1024

Overcurrent.

11

FAN

2048

Fan failure.

12-15

Not used

0

Always be 0.

Advertising