Monitor:current[:value, Monitor:power:condition, Monitor:current[:value] -47 – RIGOL DP832A User Manual

Page 71: Monitor:power:condition -47, Monitor:current[:value] :monitor:power:condition

Advertising
background image

Chapter 2 Command System

RIGOL

DP800 Programming Guide

2-47

:MONItor:CURRent[:VALue]

Syntax

:MONItor:CURRent[:VALue] {<value>|MINimum|MAXimum}
:MONItor:CURRent[:VALue]? [MINimum|MAXimum]

Description

Set the current value of the monitor condition (the current channel).
Query the current value of the monitor condition (the current channel).

Parameter

Name

Type

Range

Default

<value>

Real

Refer to the "Explanation"

Explanation

For multi-channel models, the range of <value> is from 0 to the maximum current

of the current channel and the default is 0.5*rated current of the current channel;

for single-channel model, the range of <value> is from 0 to the maximum current

of the current range and the default is 0.5*rated current of range 1.

Return Format

The query returns the current of the monitor condition (the current channel), for

example, 4.0000.

Example

:MONI:CURR 4 /*Set the current value of the monitor condition (the current

channel) to 4A*/

:MONI:CURR? /*Query the current value of the monitor condition (the current

channel) and the query returns 4.0000*/

Related

Command

:MONItor:CURRent:CONDition

:MONItor:POWER:CONDition

Syntax

:MONItor:POWER:CONDition {<P|>P|NONE}
:MONItor:POWER:CONDition?

Description

Set the power monitor condition of the monitor (the current channel).
Query the power monitor condition of the monitor (the current channel).

Parameter

Name

Type

Range

Default

{<P|>P|NONE}

Discrete

<P|>P|NONE

NONE

Explanation

 You can set the power monitor condition to "<P" (<power), ">P" (>power) or

"NONE". "NONE" indicates that the instrument will not monitor the power.

 The actual monitor condition is the logic combination of the voltage, current

and power.

 You can send the

:MONItor:POWER[:VALue]

command to set the power

monitor value.

Return Format

The query returns the power monitor condition, for example, <P.

Example

:MONI:POWER:COND <P /*Set the power monitor condition (the current

channel) to "<P"*/

:MONI:POWER:COND? /*Query the current power monitor condition and the

query returns <P*/

Related

Commands

:MONItor:POWER[:VALue]

:MONItor:CURRent:CONDition
:MONItor:CURRent[:VALue]
:MONItor:VOLTage:CONDition
:MONItor:VOLTage[:VALue]

Advertising