Output:sense, Output[:state, Output:sense -63 – RIGOL DP832A User Manual

Page 87: Output[:state] -63

Advertising
background image

Chapter 2 Command System

RIGOL

DP800 Programming Guide

2-63

:OUTPut:SENSe

Syntax

:OUTPut:SENSe [CH1|CH2|CH3,]{ON|OFF}
:OUTPut:SENSe? [CH1|CH2|CH3]

Description

Enable or disable the Sense function of the channel.
Query the status of the Sense function of the channel.

Parameter

Name

Type

Range

Default

[CH1|CH2|CH3]

Discrete

CH1|CH2|CH3

None

{ON|OFF}

Bool

ON|OFF

OFF

Explanation

 In large current output, to ensure that the load can acquire accurate voltage

drop, CH2 of DP821A/DP821 and DP811A/DP811 provide Sense (remote

sense) working mode. In this mode, the voltage at the load terminal instead of

the output voltage of the power supply is measured to compensate the voltage

drop caused by the load lead automatically.

 This command is only applicable to the channels (DP821A/DP821 (CH2) and

DP811A/DP811) that support the Sense function. For channels that do not

support the Sense function, the query returns NONE.

 DP821A/DP821/DP811A/DP811 provides output terminal on the front panel for

the Sense working mode. Besides, the output interface on the rear panel of

DP811A/DP811 can also be used for the Sense working mode. But, only one

output mode can be selected at one time and the output terminal on the front

panel can provide higher precision than the output interface on the rear panel.

Return Format

The query returns ON or OFF. For channels that do not support the Sense function,

the query returns NONE.

Example

:OUTP:SENS CH1,ON /*Enable the Sense function of the DP811A channel*/
:OUTP:SENS? CH1 /*Query the status of the Sense function of the DP811A

channel and the query returns ON*/

:OUTPut[:STATe]

Syntax

:OUTPut[:STATe] [CH1|CH2|CH3,]{ON|OFF}
:OUTPut[:STATe]? [CH1|CH2|CH3]

Description

Enable or disable the output of the specified channel.
Query the output status of the specified channel.

Parameter

Name

Type

Range

Default

[CH1|CH2|CH3]

Discrete

CH1|CH2|CH3

None

{ON|OFF}

Bool

ON|OFF

OFF

Explanation

 Make sure that the current setting will not affect the device connected to the

power supply before enabling the channel output.

 When [CH1|CH2|CH3] is omitted, the system performs the corresponding

operation on the current channel.

Return Format

The query returns ON or OFF.

Example

:OUTP CH1,ON /*Enable the output of CH1*/
:OUTP? CH1 /*Query the current output status of CH1 and the query returns

ON*/

Advertising