:TIMEr:TEMPlet:OBJect

Syntax

:TIMEr:TEMPlet:OBJect {V|C},{<value>|MINimum|MAXimum}
:TIMEr:TEMPlet:OBJect? [MINimum|MAXimum]

Description

Select the editing object of the templet and set the current or voltage.
Query the editing object of the templet currently selected as well as the

corresponding current or voltage.

Parameter

Name

Type

Range

Default

{V|C}

Discrete

V|C

V

<value>

Real

Voltage or current range of the

channel currently selected

0

Explanation

When V is selected, the editing object is set to voltage and <value> is used to set

the current value; when C is selected, the editing object is set to current and

<value> is used to set the voltage value.

Return Format

The query returns the editing object currently selected and the corresponding

voltage or current value (separated by comma), for example, V,2.0000. Wherein, V

denotes that the editing object currently selected is voltage; 2.0000 denotes that

the current currently set is 2A.

Example

:TIME:TEMP:OBJ V,2 /*Set the editing object of the templet to voltage and set the

current to 2A*/

:TIME:TEMP:OBJ? /*Query the editing object of the templet as well as the

corresponding current or voltage and the query returns

V,2.0000*/