Analyzer:starttime, Analyzer:value, Analyzer:starttime -7 – RIGOL DP832A User Manual

Page 31: Analyzer:value? -7

Advertising
background image

Chapter 2 Command System

RIGOL

DP800 Programming Guide

2-7

:ANALyzer:STARTTime

Syntax

:ANALyzer:STARTTime {<value>|MINimum|MAXimum}
:ANALyzer:STARTTime? [MINimum|MAXimum]

Description

Set the start time of the analyzer.
Query the start time of the analyzer.

Parameter

Name

Type

Range

Default

<value>

Integer

Record period of the record

file opened to end time

Record period of the

record file opened

Explanation

 You can only set the start time when valid record file is opened (refer to

the

:ANALyzer:FILE?

command).

 Send the

:ANALyzer:ANALyze

command and the analyzer analyzes the

recorded data between the start time and end time.

Return Format

The query returns an integer, for example, 1.

Example

:ANAL:STARTT 1 /*Set the start time to 1s*/
:ANAL:STARTT? /*Query the current start time and the query returns 1*/

Related

Commands

:ANALyzer:ANALyze
:ANALyzer:FILE?
:ANALyzer:ENDTime

:ANALyzer:VALue?

Syntax

:ANALyzer:VALue? <time>

Description

Query the voltage, current and power at the specified time in the record file

opened.

Parameter

Name

Type

Range

Default

<time>

Integer

Start time of the record file

opened to end time

None

Explanation

This command is only valid when valid record file is opened (refer to

the

:ANALyzer:FILE?

command).

Return Format

The query returns the voltage, current and power separated by commas, for

example, Volt:1.2817V,Curr:0.0485A,Power:0.0622W.

Example

:ANAL:VAL? 5 /*Query the voltage, current and power at 5s of the record file

opened and the query returns

Volt:1.2817V,Curr:0.0485A,Power:0.0622W*/