Output:ocp[:state, Output:ocp[:state] -56 – RIGOL DP832A User Manual

Page 80

Advertising
background image

RIGOL

Chapter 2 Command System

2-56

DP800 Programming Guide

:OUTPut:OCP[:STATe]

Syntax

:OUTPut:OCP[:STATe] [CH1|CH2|CH3,]{ON|OFF}
:OUTPut:OCP[:STATe]? [CH1|CH2|CH3]

Description

Enable or disable the overcurrent protection (OCP) function of the specified

channel.
Query the status of the overcurrent protection (OCP) function of the specified

channel.

Parameter

Name

Type

Range

Default

[CH1|CH2|CH3]

Discrete

CH1|CH2|CH3

None

{ON|OFF}

Bool

ON|OFF

OFF

Explanation

 When the overcurrent protection function is enabled, the output will turn off

automatically when the output current exceeds the overcurrent protection

value currently set (

:OUTPut:OCP:VALue

). You can send

the

:OUTPut:OCP:ALAR?

or

:OUTPut:OCP:QUES?

command to query whether

overcurrent protection occurred on the specified channel currently.

 When [CH1|CH2|CH3] is omitted, the system executes the corresponding

operation on the current channel.

Return Format

The query returns ON or OFF.

Example

:OUTP:OCP CH1,ON /*Enable the overcurrent protection function of CH1*/
:OUTP:OCP? CH1 /*Query the status of the overcurrent protection function of

CH1 and the query returns ON*/

Related

Commands

:OUTPut:OCP:ALAR?
:OUTPut:OCP:QUES?

:OUTPut:OCP:VALue

Advertising
This manual is related to the following products: