4 2-wire ports, Wire ports, For the 2-wire ports. see – Telex RTS OMS OMNEO Main Station Advanced Digital Partyline Intercom Base (5-Pin Female) User Manual

Page 104: Wire

Advertising
background image

104

en | Configuration | Ports menu

OMS OMNEO Main Station

01-2021 | 03 | F.01U.380.820

Technical Manual

Bosch Security Systems, LLC

IP Address Field

Use the

IP Address

field to enter the IP address of the RVON device to which this port should

connect.

Codec Field

Use the

Codec

field to select the codec type for the RVON port.

Available options for this field is G.711a, G.711µ, G.722, and G.729A.

Device Type Field

Use the

Device Type

field to select the type of RVON device connected to the port.

Packet Size Field

Use the

Packet Size

field to select the size of each audio packet. The packet size depends on

the codec selected.
Available options for G.711a, G.711µ, G.722 - 10 ms, 20 ms, and 30 ms; for G.729A - 10 ms, 20
ms, 40 ms, and 60 ms.

Channel Field

Use the

Channel

field to select the channel number on the device to which this port is

connected.

VAD Field

Use the

VAD

field to select the threshold at which point audio transmits across the network.

The range for this field is -60 dBm to -30 dBm, or Off.

Description Field

Use the

Description

field to enter a description for the channel.

22.4

2-Wire ports

Figure 22.8:

Configuration | Ports | 2-Wire

XLR Field

The

XLR

field displays the four 2-Wire channels (CH A, CH B, CH C, and CH D).

Port Field

The

Port

field displays the port and alpha assigned to the 2W channel.

Changes cannot be made to this field.

Mode Field

Use the

Mode

field to select the channel operation mode.

Available options are:

Off

Audiocom

Balanced Audio, shared power and audio

Clear-Com

Unbalanced, separate power and audio

RTS1

CH 1 Unbalanced, shared power and audio

RTS2

CH 2 Unbalanced, shared power and audio

Balanced and unbalanced refer to the type of audio signal being used.

Advertising