18.3

Clock

The

Clock

menu shows the status of the OMNEO audio synchronization clock. Operation of

OMNEO audio requires that all devices on the network have a synchronized clock reference.
The clock master sends a signal out to other networked devices for synchronization.

Figure 18.4:

Status | Hardware | Clock

Clock Source Field

The

Clock Source

field displays the clock mode of the device. Devices can be either the clock

master or the slave that receives the clock with which to synchronize.
Available states for this field are:

Network / Slave

OMS receives its PTP clock from another device on the network.

Internal / Master

OMS generates the PTP clock as the Master Clock for other devices
on the network.

PTP Clock Status Field

The

PTP Clock Status

field displays the synchronization status of the device to other devices

on the network. PTP (Precision Time Protocol) synchronizes clocks throughout the network.
Available status for this field are Linked or Unlinked.

Preferred Master Check Box

The

Preferred Master

check box determines whether the device is the preferred master clock.