7 display options, Display options – Telex RTS OMS OMNEO Main Station Advanced Digital Partyline Intercom Base (5-Pin Female) User Manual

Page 121

Advertising
background image

OMS OMNEO Main Station

Configuration | Local Keypanel menu | en

121

Bosch Security Systems, LLC

Technical Manual

01-2021 | 03 | F.01U.380.820

unlatched when the footswitch releases. In this mode, the footswitch is a one-time operation.
Pressing the footswitch turns the keys on and releasing the footswitch turns the keys off,
unlatching them so the keys are unable to come on again with the next press of the
footswitch. To use the footswitch again, the desired keys must be re-latched.
A footswitch is a foot-triggered switch used to activate keypanel keys. OMS provides two
methods for activating the footswitch feature:

Opto-isolated input #1 on the GPIO terminal block, located on the rear panel.

Figure 24.7:

Footswitch Cabling

Pin 6 on the headset connector.

By default, the footswitch is disabled.

Figure 24.8:

Configuration | Local Keypanel | Footswitch Screen

Enable Footswitch Check Box

The

Enable Footswitch

check box determines whether to enable the footswitch for the

device.

Unlatch Keys on Release Check Box

The

Unlatch Keys on Release

check box determines whether latched talk keys become

unlatched when the user releases the footswitch.

24.7

Display Options

Use the Display Options page to configure panel volume and listen assignment display
options.

Figure 24.9:

Configuration | Local Keypanel | Display Options Screen

Show Panel Volume Check Box

The

Show Panel Volume

check box determines whether the speaker/headset volume window

permanently displays, otherwise the window only appears when adjusting the volume.

Advertising