background image

OMS OMNEO Main Station

Configuration | Ports menu | en

105

Bosch Security Systems, LLC

Technical Manual

01-2021 | 03 | F.01U.380.820

Unbalanced
Audio

uses ground reference signaling

Balanced Audio

uses differential signaling

By default, this field is set to Off.

Loop Field

Use the

Loop

field to configure a pair of ports to act as a loop in and loop out connectors. CH

B can be configured as a loop out connector for CH A. Additionally; CH D can be configured as
a loop out connector for CH C.
Configuring a pair of connectors for looping allows greater flexibility when installing the 2-Wire
wiring.

1

2

RTS

Monitor

Power

PS-20 Power Supply

PGM

Select

PGM
Level

4ch

2

4

2

4

2ch 1

2

1

2

U N IVER S AL

B ELTPACK

-5000

B P

Figure 22.9:

Loop configuration for CH A and CH B

i

Notice!

When XLR-A and XLR-B are looped, this means both connectors are supporting the same pair
of RTS-1 and RTS 2 channels and these ports to the intercom are port CH A and port CH B.

Auto-Mute Field

Use the

Auto-Mute

field to determine whether the 2W port automatically mutes. If the setting

is enabled, the 2W port is muted whenever OMS detects the absence of DC power on the line
(typically, because the cable on the 2W port was removed).
By default, the Auto-Mute is enabled.

Advertising