4 debug shell, 2 gpio-16 menu, 3 clock select – Telex RTS OMS OMNEO Main Station Advanced Digital Partyline Intercom Base (5-Pin Female) User Manual

Page 131: Debug shell, Gpio-16 menu, Clock select, Gpio-16, Devices. see

Advertising
background image

OMS OMNEO Main Station

Configuration | Advanced menu | en

131

Bosch Security Systems, LLC

Technical Manual

01-2021 | 03 | F.01U.380.820

26.1.4

Debug Shell

Figure 26.6:

Configuration | Authentication | Debug Shell

Access Field

Use the

Access

field to grant access to the debug.

Telnet is available on the Control Port.
Available options are Enabled and Disabled (default).

26.2

GPIO-16 menu

Use the

GPIO-16

menu to set the IP addresses of the GPIO-16 devices. OMS uses the Control

Port to communicate to GPIO-16 devices.

Figure 26.7:

Configuration | Advanced | GPIO-16 Screen

To

configure the GPIO-16 IP address

, do the following:

1.

Navigate to the

desired position

.

2.

Click the

ENC2 encoder knob

.

The field becomes active.

3.

Set the

IP address

.

4.

Click the

ENC2 encoder knob

.

5.

Click the

ENC1 encoder knobto exit the screen

.

A Changes Made message appears.

6.

Navigate to the

desired action

.

7.

Click the

ENC2 encoder knob to confirm

.

26.3

Clock Select

Use the

Clock Select

screen to configure the OMNEO audio PTP clock used to synchronize

audio in an intercom system.

Figure 26.8:

Configuration | Advanced | Clock Select

Preferred Master Check Box

The

Preferred Master

check box determines whether the device is configured as the preferred

master clock for other OMNEO devices on the network.
By default the Preferred Master field is not selected.

Advertising