Telex RTS OMS OMNEO Main Station Advanced Digital Partyline Intercom Base (5-Pin Female) User Manual

Page 130

Advertising
background image

130

en | Configuration | Advanced menu

OMS OMNEO Main Station

01-2021 | 03 | F.01U.380.820

Technical Manual

Bosch Security Systems, LLC

Figure 26.5:

Configuration | Authentication | Front Panel

i

Notice!

If the PIN is set, and then forgotten go to AZedit | Options | OMS Front Panel to reset the PIN.

Access Field

Use the

Access

field to set the level of security for the OMS front panel.

Available options are:

Unrestricted
(default)

The front panel has full access without any restrictions

Read Only

The front panel is read only. No modifications can be made to any menu
items.

Authenticated

The user must enter a PIN to access the front panel.

Disabled

The front panel has no access.

Timeout Field

Use the

Timeout

field to set the amount of time the front panel is idle before the user must re-

enter a PIN when access is set to authenticated and a PIN is set.

i

Notice!

The front panel can be forced to logout (or forget a PIN has been entered) by manually
activating the screen saver. To do this, press and hold the ENC1 encoder knob.

Available options are 1 minute to 15 minutes.
The default for this field is 2 minutes.

Status PIN Field

Use the

Status PIN

field to enter a numeric PIN used to access the Status menu. If a Status

PIN is set, the user must enter the PIN to access any area on the front panel (for example, the
Alarms menu is inaccessible without PIN).
This field can contain up to 20 digits.

Setup PIN Field

Use the

Setup PIN

field to enter a numeric PIN used to access the Intercom Setup menu.

This field can contain up to 20 digits.

Config PIN Field

Use the

Config PIN

field to enter a numeric PIN used to access the Configuration menu.

This field can contain up to 20 digits.