en | Status | Network menu

OMS OMNEO Main Station

01-2021 | 03 | F.01U.380.820

Technical Manual

Bosch Security Systems, LLC

Figure 14.5:

Status : Network : RVON screen

Link Up Field

The

Link Up

field displays the status of data communication on the RVON port.

Available statuses are:

The link is up

The link is not up, but an IP address is defined

No IP address is defined

Speed Field

The

Speed

field displays the transmission speed over the RVON port.

The Ethernet links support 100 Mbps or 1 Gbps.

Duplex Field

The

Duplex

field displays the transmit mode the RVON network connection is currently

operating.
Almost all Ethernet interfaces auto-negotiate to full duplex. If the interface displays half duplex
mode, this typically signifies the auto-negotiate failed, resulting in network collisions and
errors.
Available options for this field are:

Half-Duplex

Can either transmit or receive, but not both simultaneously

Full-Duplex

Can transmit and receive simultaneously