<6. CALORIE / PARAMETER SETTING>

6-10

IM 11T3E1-01E

(3) Display Mode
Select one of the following seven parameters to be shown in the message field. Each press of

the [NO] key cycles through the choices in the order shown below:

1. Physical density [XX.XXXX KG/M3] or [XX.XXXX LB/FT3]

(depends on the setting of CODE 21)

2. Compensated density [X.XXXX KG/M3 ]or [X.XXXXX LB/FT3]

(depends on the setting of CODE 21)

3. Calorific value [XXX.XXX MJ/M3] or [XX.XXXX KBTU]

(depends on the setting of CODE 22)

4. Temperature [XXX.X °C] or [XXX.X °F]

(depends on the setting of CODE 23)

5. Pressure [XXX.XX KPA] or [X.XXXX MPA] or [XX.XXX PSI]

(depends on the setting of CODE 20)

6. Current for analog output 1 (%) [XXX.X MA1%]

7. Current for analog output 2(%) [XXX.X MA 2%]

Show the desired choice and press the [YES] key. That choice is set as a parameter to be meas-

ured in the measurement mode (<MEASURE>). Parameters 1, 2 and 3 are configurable, while

parameters 4 to 7 are read-only.