U41117-J-Z125-7-76

Main window

GXCC

An error flag (yellow or pink) can be displayed only if the Infobroker has been

started and is operational. Consequently in certain situations, especially during
the boot phase of individual ISPs, it can occur that an overall status of turquoise
(OK) is displayed even though the status of individual ISPs is shown as not op-
erational in the GXCC main window.

Further information is provided in

section “GXCC as a monitoring tool without

SNMP” on page 549

.

Profile file
Name of the profile file. This can be specified on startup using the -profile parameter,
or selected from the function bar at any time.

CentricStor version

ID=<IP-address>:<host-name>:<port-numer>
Host features with which you monitor CentricStor

Conn:n
Number of connections which exist to the monitored system

Connection mode (MP: Multi-Port, SP: Single-Port)

GXCC mode
Access permissions under which GXCC is currently running:
SERVICE

GXCC is running in Service mode

USER

GXCC is running in User mode

OBSERVE/OBSV

GXCC is running in Observe mode

Scale
Display scale set under “Options Settings” (see the section

“Settings” on page 153

).

Autoscan
Text color indicating the operating status of the Autoscan facility:
Green:

Autoscan active

Yellow:

Alignment with the InfoBroker currently in progress

Red, flashing: Autoscan temporarily stopped
White:

Locked (Simulation mode)

The Autoscan process will also be stopped temporarily for certain operations. In this
case, the text color switches back to green once the operation in question is completed.

The Autoscan facility is described in more detail on

page 152

.

Scan mode
S

Scan rate determined automatically (self-adjusting)

M

Scan rate set manually (see the section

“Settings” on page 153

)

i

i