FUJITSU CentricStor V3.1D User Manual

Page 499

Advertising
background image

U41117-J-Z125-7-76

499

Explanation of console messages

Message lines

SXSM010

sma#: Memory Module <Id> disabled

ALERT
SXSM010

sma#: Memory Module disabled; Module# = <Id>

ALERT

Meaning
Memory module <Id> is in the “disabled” state. This can be caused by the following:
a) The memory module was disabled in the BIOS setup.
b) The memory module was enabled in the BIOS setup, but has been disabled because

of too many memory errors.

Response
Notify maintenance staff.

SXSM011

sma#: Correctable Memory Error occurred; Module# = <Id>

ALERT

Meaning
A correctable memory error has occurred in memory module <Id>.

Response
Notify maintenance staff.

SXSM012

sma#: Uncorrectable Memory Error occurred; Module# = <Id>

ALERT

Meaning
An uncorrectable memory error has occurred in memory module <Id>.

Response
Notify maintenance staff.

SXSM016

sma#: Fan <Id>: Fan failed

ALERT

Meaning
Non-redundant fan <Id> has failed and must be replaced.

If the fan is inoperable for more than 3 minutes, the SINIX system is shut down and the
server deactivated to prevent the server from overheating.

Response
Notify maintenance staff.

SXSM017

sma#: Fan <Id>: Redundant fan failed

ALERT

Meaning
Redundant fan <Id> has failed. As this fan is redundant, the SINIX system is not shut down.

Response
Notify maintenance staff.

Advertising