28

U41117-J-Z125-7-76

Hardware architecture

CentricStor - Virtual Tape Library

2.2.1.2

ICP (Integrated Channel Processor)

The ICP is the interface to the host systems connected in the overall system.

Figure 5: External and internal ICP connections

Depending on the type of host system used, it is possible to equip an ICP with a maximum
of 4 ESCON boards on the host side (connection with BS2000/OSD, z/OS or OS/390), with
one or two FICON ports (connection with z/OS or OS/390), or with one or two FC boards
(BS2000/OSD or open systems). A mixed configuration is also possible.The ICP also has
an internal FC board (or two in the case of redundancy) for connecting to the RAID disk
system.

The main task of the ICP is to emulate physical drives to the connected host systems.

The host application issues a logical mount job for a logical drive in an ICP connected to a
host system (see

section “Issuing a mount job from the host” on page 39

). The data trans-

ferred for the associated logical volume is then stored by the ICP directly in the RAID disk
system.

The virtual CentricStor drives support a maximum block size of 256 KB.

Communication with the other processors takes place over a LAN connection.

FC

ESCON

FC

ICP

FC

FCP

FC

ICP

Hosts

CentricStor

BS2000/OSD,

Open Systems

LAN

z/OS and OS/390

FC

FICON

FC

ICP

z/OS and OS/390

BS2000/OSD,

i

Advertising