483

Explanation of console messages

Message lines

SXPS006

PLS(#4006) ERROR: <robot error message>

Meaning
A general robot error which is not necessarily traceable to a device or a cassette.
The meaning of the error message can be found in the relevant robot documentation.

Response
The robot error messages are mostly self-explanatory.
Typical reasons for errors include:

Communication errors:

LAN connection to the AMU PC or ACSLS server is defective

Incorrect IP address for the AMU PC or ACSLS server in the VLP

Incorrect IP address for the VLP in the AMU PC (Check of file \mptn\etc\hosts
in AMU-PC)

There is no address for the AMU PC or ACSLS server in the VLP’s /etc/hosts

There is no system name (SYSNAME in vtls.conf) in the VLP’s /etc/hosts

Client not defined in robot software (AMU-PC, LMF Lite Server)

Robot problems

Error in the configuration file of the AMU PC (in the case of ADIC-AML robots)

Cartridge is jammed

Cartridge has fallen out of the grab attachment, etc.

Notify maintenance staff.

SXPS007

PLS(#4007):ERROR: <PDS-name>: <robot error message>

Meaning
The robot is experiencing difficulties loading or unloading the device designated by the PDS
number.

Response
Notify maintenance staff.

SXPS008

PLS(#4008) ERROR: 'vsn' <robot error message>

Meaning
The robot has difficulty loading or unloading the cassette described by ’vsn’.

Response
Check the cassette described by 'vsn'. There may be a problem in reading the barcode.

SXPS096

PLS(#996) NOTICE: Stop `PLS-name` for Maintenance

Meaning
The PLS `PLS-name` was stopped via the GUI.