Sxrd... (fibrecat: raid), 15 sxrd... (fibrecat: raid) – FUJITSU CentricStor V3.1D User Manual

Page 485

Advertising
background image

U41117-J-Z125-7-76

485

Explanation of console messages

Message lines

9.2.15

SXRD... (FibreCAT: RAID)

The table below shows the message numbers with the RAID systems which issue the
messages:

9.2.15.1

Messages of the monitoring daemon for the internal RAID

Messages during ongoing operation

SXRD001

NOTICE: raidd: 0:BBU - charging [xx] completed

SXRD001

NOTICE: raidd: 0:BBU - charging [xx] in progress

Meaning
These messages are normal when the BBU on controller 0 is in operation.

SXRD001

ALERT: raidd: 0:BBU - charging [xx] failed

SXRD001

ALERT: raidd: 0:BBU - pack not present

SXRD001

ALERT: raidd: 0:BBU - module not present

SXRD001

ALERT: raidd: 0:BBU - high temp

SXRD001

ALERT: raidd: 0:BBU - low voltage

SXRD001

ALERT: raidd: 0:BBU - cycles exceeded

Meaning
These messages indicate a hardware problem with the BBU on controller 0.

Response
Notify maintenance staff.

SXRD001

ALERT: raidd: 0:0:1 - disk state changed (Online -> Dead)

Meaning
The physical disk of controller 0, channel 0, target ID 1 has failed. All the associated logical
disks are without redundancy.

Response
Notify maintenance staff.

Message number

RAID system

Page

SXRD001
SXRD100 - SXRD104

internal RAID

485

SXRD002 - SXRD009

S80

488

SXRD010

CX500, CX3-20

489

SXRD501, SXRD901

CX500, CX3-20

490

Advertising