FUJITSU CentricStor V3.1D User Manual

Page 487

Advertising
background image

U41117-J-Z125-7-76

487

Explanation of console messages

Message lines

SXRD001

ALERT: raidd: c50d0 - state is Critical

Meaning
This message is only generated when the raidd is started at system boot. The logical disk
0 on controller 0 no longer provides any redundancy. This indicates a hardware problem
with a physical disk belonging to the addressed logical disk.

Response
Notify maintenance staff.

SXRD001

ALERT: raidd: c50d0 - state is Offline

Meaning
This message is only generated when the raidd is started at system boot. A further physical
disk belonging to the logical disk 0 on controller 0 has failed. The addressed logical disk is
no longer accessible.

Response
Notify maintenance staff.

SXRD100

ALERT: c50d0 RAID-1, Critical, 17300 MB, Write Back

Meaning
Logical disk 0 of controller 0 has no error redundancy.

Response
Notify maintenance staff.

SXRD101

ALERT: c50d0 RAID-1, Offline, 17300 MB, Write Back

Meaning
Logical disk 0 of controller 0 is not operable.

Response
Notify maintenance staff.

SXRD102

ALERT: raid 0:1:0 - Disk: Dead, 17300 MB

Meaning
The physical disk of controller 0, channel 1, target ID 0 has failed. All the associated logical
disks are without redundancy.

Response
Notify maintenance staff.

SXRD103

NOTICE: raid 0:1:0 - Disk: Standby, 17300 MB

Meaning
The physical disk of controller 0, channel 1, target ID 0 is not active.

Advertising