FUJITSU CentricStor V3.1D User Manual

Page 471

Advertising
background image

U41117-J-Z125-7-76

471

Explanation of console messages

Message lines

ERR_PDS_03_POS_NOT_AFTER_TAPEMARK

Meaning
Positioning error: There is no tape marke immediately in front of the read/write position that
is to be adopted. The block position transferred is presumably not correct.

Response
Evaluate the physical error code and sense bytes. It may be that the PLM has transferred
an incorrect block number. If you think this is the case, save the diagnostic documentation.

SXPL017

PLM(#17) ERROR: <PDS-name> reports error = <PDS-error-string> on PV <PV-name>

Meaning
The PDS <PDS-name> has reported a class-2 error (TFS errors). Class-2 errors are all
errors which occur when accessing the TFS (access, open, read, write).

Response
The meaning of the error texts transferred in <PDS-error-string> and any actions to be
taken are listed below.

List of the error strings reported with PLM(#17)

ERR_PDS_02_GENERIC

Meaning
Generic error

Response
Notify maintenance staff.

ERR_PDS_02_OPEN

Meaning
Possible causes:

Error while opening the TFS cache file

File ID is not correct (-F)
Through asynchronous backup of the logical volume to tape with a time delay caused
by other backup jobs or long positioning times on the tape, the host can have modified
the logical volume in the meantime and thus have changed the file ID. The backup is
started again by this modification.

Illegal path name

No write/read access to file

Response
Notify maintenance staff.

ERR_PDS_02_READ

Meaning
Error while reading from the cache file