Pls (physical library service), Object information on the pls, Functions for individual plss – FUJITSU CentricStor V3.1D User Manual

Page 417: Functions for all plss, 19 pls (physical library service)

Advertising
background image

U41117-J-Z125-7-76

417

XTCC

PLS (Physical Library Service)

8.19 PLS (Physical Library Service)

8.19.1

Object information on the PLS

Each physical library is assigned at least one PLS (Physical Library Server).

The PLS of a SCSI-controlled archive must run on the ISP that contains the associated
SCSI controller. The easiest way of identifying the location of a PLS is to use the Global
Status Monitor. By resting the mouse pointer on a PLS symbol, you can open an information
box which among other things specifies the associated ISP.

As in XTCC, the status of the PLS is indicated by the colors pink (stopped), green (running),
and green/brown (running with the trace switched on). In the event of an error, this is
indicated by means of a red triangle.

The example below shows the object information of an archive controlled via SCSI (left), via
LAN (center), and a CASHION archive controlled via serial interface (right):

The following information is displayed:

Name

Name assigned during configuration and displayed in the PLS symbol.

Type

Type of access system (SCSI, STKCSC, STLACI, CASHION or LMF).

Address

SCSI address (controller, target, LUN) or SINIX name of the access system.

Accessor

Internal device name of the library (device node with SCSI, otherwise IP
address or server name).

Error

Only in the event of an error. Message indicating the cause of the error.

Autostart

Enabled / disabled.

8.19.2

Functions for individual PLSs

There are no PLS functions available in Observe and User mode.

8.19.3

Functions for all PLSs

No functions for all PLSs are available.

SCSI archive:

STK archive:

CASHION archive: