U41117-J-Z125-7-76

225

GXCC

Function bar

Number of Cleaning Cycles

Only applies to cleaning cartridges: the number of cleaning cycles still possible for
the inserted cartridge (decimal value).

Flag “Omit Header Check”

Only applies to data cartridges: The header of an added volume is always
overwritten with a CentricStor header without exception. This means that you can
also add volumes that have been taken out of CentricStor but that have not been
deleted using “Erase” (see the

section “Physical Volume Operations » Erase

Physical Volumes” on page 226

).

CAUTION!

This flag should only be used under exceptional circumstances. If you use
this flag and accidently specify the number of an active volume, the user
data of this volume will be overwritten without exception.

Buttons along the bottom border

OK

The cartridges are checked (see below: “Actions linked with “OK”) and, in the event of
a positive result, included in the PLM data maintenance system.

Cancel

The window is closed without any further activity.

Actions linked with “OK”

1. If the PVG is already assigned to an LVG and the LV size of this LVG is > 2 GB, the

capacity of the new PV must be >= the defined LVG capacity. Here it must be borne in
mind that a PVG can be assigned to multiple LVGs and that the largest LV size is used
for the capacity check. If the PV capacity is lower, the assignment is rejected with the
following message:

PLM(#55): WARNING: Capacity of PV 0F3171 is too small for PVG RALF;
PV-file will be removed!

2. A check is made to see whether the cartridge type (cleaning or data) is correct. The

number of cleaning cycles cannot be verified for all cartridge types.

As cleaning cartridges are consumables a suitable number of cleaning cycles

should always be available in the libraries. When the soft limit is reached, 10
cleaning cycles are available per drive.

!