U41117-J-Z125-7-76

Message lines

Explanation of console messages

SXRD001

NOTICE: raidd: 0:0:1 - disk state changed (Dead -> Write-Only)

Meaning
A rebuild is active for the physical disk of controller 0, channel 0, target ID 1.

SXRD001

NOTICE: raidd: 0:0:1 - disk state changed (Dead -> Online)

Meaning
A rebuild was successful for the physical disk of controller 0, channel 0, target ID 1. All the
associated logical disks are fully operational (redundant) again.

SXRD001

ALERT: raidd: c50d0 - state changed (Online -> Critical)

Meaning
The logical disk 0 on controller 0 no longer provides any redundancy. This indicates a
hardware problem with a physical disk belonging to the addressed logical disk.

Response
Notify maintenance staff.

SXRD001

ALERT: raidd: c50d0 - state changed (Critical -> Offline)

Meaning
A further physical disk belonging to the logical disk 0 on controller 0 has failed. The
addressed logical disk is no longer accessible.

Response
Notify maintenance staff.

SXRD001

NOTICE: raidd: c50d0 - state changed (Critical -> Online)

Meaning
The logical disk 0 on controller 0 has completed a rebuild and once again provides redun-
dancy.

Messages during the start phase

SXRD001

ALERT: raidd: 0:0:3 - disk state is Dead

Meaning
This message is only generated when the raidd is started at system boot. The physical disk
on controller 0, bus 0, target 3 was failed as the system booted. This indicates a hardware
problem with the addressed physical disk.

Response
Notify maintenance staff.

SXRD001

ALERT: raidd: 0:0:3 - disk state is Write-Only

Meaning
This message is only generated when the raidd is started at system boot. As the system
was started a rebuild was active for the physical disk on controller 0, bus 0, target 3.