Explanation of console messages

SXVW053

VLPWATCH: NOTICE: VW(#053) AutoVLP-Failover: system error of getx2kvp()!

Meaning
An error occurred while checking the license.

Response
Check the license.

SXVW054

VLPWATCH: NOTICE: VW(#054) AutoVLP-Failover: error of %d=getx2kvp()!

Meaning
An error occurred while checking the license.

Response
Check the license.

SXVW055

VLPWATCH: ERROR: VW(#055) AutoVLP-Failover: no reboot to switch!: %s

Meaning
The statement for the explicit switchover was issued on the VLP. The SVLP is not available
or the VLPwatch daemon is not running:

%s = SVLP is not alive!
%s = SVLP is not alive (%d Seconds)!
%s = SVLP (%s) is alive; VLPwatch on %s not running!

Response
The SVLP must be checked and the AutoVLP function must be activated!

SXVW056

VLPWATCH: ERROR: VW(#056) AutoVLP-Failover: no reboot to switch: not a VLP!

Meaning
The statement for the explicit switchover was issued on an SVLP. However, it may only be
issued on the VLP.

Response
Issue the statement for explicit switchover (“swap master”) on the VLP.

SXVW057 VLPWATCH: ALERT: VW(#057) AutoVLP-Failover: LAN_0 connection is DOWN on SVLP;

Failover not functional!

Meaning
The SVLP has no connection to the internal LAN. The AutoVLP failover function is not wor-
king.

Response
Investigate and correct the LAN connection problem.